126
Views
13
CrossRef citations to date
0
Altmetric
ATOMIC SPECTROSCOPY

Determination of Silicon in Lubricant Oil by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry Using Least-Square Background Correction and Internal Standardization

, , , &
Pages 2150-2161 | Received 25 Jun 2010, Accepted 15 Sep 2010, Published online: 12 Aug 2011
 

Abstract

The least-squares background correction (LSBC) and internal standardization procedures were combined to eliminate spectral interferences caused by the CS molecular band (251.602 nm) and transport effects for determining Si in sulfuric acid digests of lubricant oil by high-resolution continuum source flame atomic absorption spectrometry. Aluminum, Ba, Ti, V, and W were tested as internal standard (IS) candidates, and W provided the best results. For absorbance measurements of solutions containing 0.5–5.0 mg L−1 Si in the presence of 25 mg L−1 W (at the wavelength integrated absorbance equivalent to 3 pixels), the correlation coefficient for the ratio of absorbance of Si to absorbance of W vs. analyte concentration was 0.9978. Fluctuations in analytical signals due to variations in sulfuric acid concentrations or acetylene/nitrous oxide flow-rate ratios were corrected by using this calibration plot. Relative standard deviations varied from 1.9 to 7.2% and 2.1 to 5.4% (n = 12) with and without LSBC/IS, respectively. Recoveries for samples spiked with 2.0 mg L−1 Si in 5.0% (v/v) sulfuric acid were within the 72.5–82.5% and 94.0–99.0% ranges without correction and by LSBC associated with internal standardization procedure, respectively. Accuracy of the proposed method was checked for the determination of Si in commercial lubricant oils and results obtained with internal standardization were better than those without correction.

Acknowledgments

The authors thank the Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) for financially supporting this work and for a fellowship to S. R. Oliveira. They are also grateful to the Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) for grants and fellowships to J. L. Raposo, Jr., J. A. Nóbrega, and J. A. Gomes Neto.

Notes

*All solutions contain 25.0 mg L−1 W as internal standard.

*NIST 1848 Lubricant Oil Additive Package. Certified value: 0.005 ± 0.0002% (m/m) or 0.60 mg L−1 (600 mg of SRM digested and diluted to 50 mL).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.