190
Views
3
CrossRef citations to date
0
Altmetric
LIQUID CHROMATOGRAPHY

Surfactant-Based Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction Determination of Corticosteroids Followed by HPLC-DAD

, , &
Pages 589-604 | Received 13 Aug 2012, Accepted 06 Sep 2012, Published online: 19 Feb 2013
 

Abstract

Surfactant-based ultrasound-assisted dispersive liquid–liquid microextraction (UA-DLLME) and derivatization were applied for the pretreatment of three corticosteroids prior to determination by high-performance liquid chromatography diode array detector (HPLC-DAD). An appropriate mixture of Triton X-100 (disperser solution), CCl4(Carbon tetrachloride; extraction solvent), and salicylaldehyde (derivatization reagent) was added to human urine and plasma samples. Extraction and derivatization were continuously performed. Some key parameters, including the nature and volume of extraction solvent and dispersive solvent, amount of derivatization reagent, extraction time and temperature effect were investigated. Linearity was investigated from 1 to 300 ng mL−1. All correlation coefficients of the calibration curves were higher than 0.9993. The recoveries of 80.36% to 87.60% and an enrichment factor of 50 were obtained with only 5.00 mL of sample. The LODs thus estimated were 0.014 ng mL−1 for beclomethasone dipropionate, 0.021 ng mL−1 for hydrocortisone, and 0.314 ng mL−1 for Nandroloniphenylpropionas, respectively, while the relative standard deviations(RSD) varied between 1.66% and 2.72% (n = 6). The results showed that the method is applicable to the determination of trace corticosteroids in human urine and plasma samples.

Acknowledgments

This study was supported by the Department of Hepatobiliary Surgery, Kunming General Hospital, Chengdu Military Region, Kunming 650032, China; the Medical Neurobiology Key Laboratory of Kunming University of Science and Technology, Basic and Applied Research Project in Yunnan province (2008ZC082 M); and the Analysis and Testing Foundation of Kunming University of Science and Technology (No. 2011294).

Notes

Note: The contents of comparison: extraction methods, analytical devices, linear range, RSD, LOD, and enrichment factor.

a Linear range.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.