195
Views
13
CrossRef citations to date
0
Altmetric
ENVIRONMENTAL ANALYSIS

Determination of Tetracyclines in Water by Ethyl Acetate–Ionic Liquid Dispersive Liquid–Liquid Microextraction and High-Performance Liquid Chromatography

, , , , &
Pages 1783-1795 | Received 13 Nov 2013, Accepted 05 Jan 2014, Published online: 26 Jun 2014
 

Abstract

An ethyl acetate-assisted ionic liquid dispersive liquid–liquid microextraction method was developed for the determination of tetracyclines in water samples with high-performance liquid chromatography using a variable wavelength detector. A mixture of ethyl acetate and 1-butyl-3-methylimidazolium hexafluorophosphate was used to isolate lanthanum(III) chelates of tetracyclines. The addition of ethyl acetate significantly enhanced the extraction efficiencies. Experimental parameters affecting the efficiency such as the identity and volume of ionic liquid, the volume of ethyl acetate, chelating time, centrifuge time, pH, and ionic strength were evaluated. Under the optimum conditions, the calibration curves were linear and the correlation coefficients (r 2 ) ranged from 0.9985 to 0.9992 over concentration levels of 0.01–0.50 µg mL−1. The limits of detection (signal-to-noise ratio = 3) of the method ranged from 0.97 to 1.14 ng mL−1, whereas inter- and intra-day relative standard deviations (n = 5) were between 2.4–4.3% and 3.6–6.8%, respectively. This method was used to analyze water samples and recoveries from 62.6% to 109.6% were obtained.

ACKNOWLEDGMENT

The authors are grateful to Professor Xuedong Wang of Wenzhou Medical University. The authors are also grateful to the anonymous reviewers for their suggestions and critical comments.

Notes

a Extraction conditions: water sample volume, 5.00 mL; pH, 7.0; La(III) (0.4 mmol L−1), 50.0 μL; extraction solvent ([BMIM]PF6) volume, 120 µL; assisted solvent volume, 0.5 mL; chelating time for TCs with La3+, 10 min; manual shaking time, 2 min; centrifugation time, 10 min.

b LDR, linear dynamic range.

c r 2, coefficients of correlation.

d LOD, limit of detection for S/N = 3.

e R, recovery.

f RSD, relative standard deviation (n = 5).

a RSD, relative standard deviation (n = 5).

DSPM = dispersive solid phase microextraction; SPE = solid phase extraction; IL-EA-DLLME = ethyl acetate-assisted ionic liquid dispersive liquid–liquid microextraction.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.