Abstract
This paper presents the results of an investigation of respiratory symptoms and lung function of 404 workers who had been exposed to jute dust in a jute mill. Measurement of total dust concentration and analysis of dust composition were also conducted. Most workers in the jute mill were exposed to jute dusts containing less than 5% silica, whereas a few workers were exposed to dusts containing approximately 10–15% silica. Male smokers and nonsmokers in the dust-exposed group had a higher prevalence of cough and chest tightness compared with those in the control group. Among dust-exposed workers, female nonsmokers had a significantly higher prevalence of cough, chronic bronchitis, chest tightness, and dyspnea than those in the control group. Lung function tests showed that dust-exposed workers had a greater incidence of abnormal lung function than did control workers, as measured by percentage of predicted forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1.0), and FEV1.0/FVC. Dust exposure was the main cause of respiratory symptoms and abnormal values of FEV1.0, but both cigarette smoking and dust exposure contributed to the abnormal values reported for FEV1.0.