Abstract
Theoretical equations developed in Part I of this paper1 have been evaluated experimentally using bubble size and gas flow rate as variables. Variations of bubble size and gas flow rate, which will affect the column performance of either batch or continuous bubble fractionation system, are predicted by the developed theory.
Based on theoretical development and experimental verifications, several approaches for the improvement of the bubble fractionation system are suggested.