539
Views
31
CrossRef citations to date
0
Altmetric
Original Articles

Gender differences in the circadian variations in muscle strength assessed with and without superimposed electrical twitches

, &
Pages 1473-1487 | Published online: 20 Feb 2007
 

Abstract

The circadian rhythm in muscle strength was analysed in 12 males (28 ± 4 years, 79.6 ± 12.3 kg, 1.80 ± 0.05 m) and eight females (28 ± 4 years, 60.3 ± 5.5 kg, 1.61 ± 0.08 m). After two familiarization sessions, participants were tested at six different times of the day (02:00, 06:00, 10:00, 14:00, 18:00 and 22:00 hours), the order of which was randomly assigned over 3–4 days. Rectal temperature (T rec) was measured over 30 min before each test. Peak isokinetic torques (PT) of knee extensors and flexors were then measured at 1.05 rad s−1 and 3.14 rad s−1 through a 90° range of motion. Maximal isometric voluntary contraction (MVC) of knee extensors and flexors was measured at 60° of knee flexion and the MVC of knee extensors was also assessed with superimposed electrical twitches (50 Hz, 250 V, 200 μs pulse width) in order to control for motivational effects. Three trials were performed in each condition, separated by 3 min recovery, and the highest values were retained for subsequent analyses. A significant circadian rhythm was observed for T rec in both males and females (acrophase, Φ, 17:29 and 16:40 hours; mesor, Me, 37.0 and 36.8°C; amplitude, A, 0.28 and 0.33°C for males and females, respectively). The mesor of T rec was higher in males than in females (p < 0.05). Significant circadian rhythms were observed for knee extensor PT at 3.14 rad s−1 in males (Φ, 17:06 hours; Me, 178.2 N m; A, 4.7 N m) and for knee extensor PT at 1.05 rad s−1 in females (Φ, 15:35 hours; Me, 128.7 N m; A, 3.7 N m). In males, the MVC of knee extensors demonstrated a significant circadian rhythm, but only when electrical twitches were superimposed (Φ, 16:17 h; Me, 302.1 N m; A, 13.6 N m). Acrophases of all indices of muscle strength were not statistically different between the two groups and were located in the afternoon (12:47 < Φ < 17:16 hours). The amplitude (percentage of mesor) of extensors MVC (electrically stimulated) was higher in males (6.4%) than in females (4.2%; p < 0.05). Significant circadian rhythms were not consistently observed for all indices of muscle strength whatever the gender. Our group of female subjects tended to show lower circadian amplitudes than the males. In males, maximal voluntary contraction of electrically stimulated muscles followed a circadian curve, which was not significant without the superimposed twitches. These results suggest that motivation could have a masking effect on the circadian rhythm in muscle performance and strengthen the view that peripheral factors are implicated in this rhythm.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.