443
Views
5
CrossRef citations to date
0
Altmetric
Article

Using trunk posture to monitor heat strain at work

, , , , , , & show all
Pages 1560-1568 | Received 11 Aug 2017, Accepted 29 Jun 2018, Published online: 08 Jan 2019
 

Abstract

This study aimed to determine if trunk posture during walking is related to increases in rectal temperature (Tre). 24 males treadmill walked in one of four conditions (1): 30 min at 3.0 mph and 0% grade, 20 °C and 50% relative humidity (RH), wearing healthcare worker (HCW) PPE; (2): 30 min at 3.0 mph and 0% grade, 27.5 °C and 60% RH, HCW PPE; (3): 30 min at 3.0 mph and 0% grade, 32.5 °C and 70% RH, HCW PPE; and (4): 40 min at 40% VO2max, 30 °C and 70% RH, wearing firefighter PPE. Trunk posture (Zephyr BioHarness 3) and Tre were measured continuously. Tre was positively related to trunk posture, controlling for covariates (B = 3.49, p < .001). BMI and age moderated this relationship (Tre×age, B = 0.76, p < .001; Tre*BMI, B = −1.85, p < .001). Trunk posture measurement may be useful in monitoring fall potential and magnitude of heat stress of workers in hot environments.

Practitioner Summary: Occupational hyperthermia increases worker risk for heat illness and injury but is difficult to monitor in the field. This investigation shows that trunk posture is independently and positively related to core temperature. Non-invasive measurement or visual inspection of trunk posture could provide novel insight on individual heat strain level.

Acknowledgements

The authors would like to acknowledge the study participants who generously volunteered their time to participate in this study. The findings and conclusions in this report are those of the authors and do not necessarily represent the views of the National Institute for Occupational Safety and Health. Mention of company names or products does not constitute endorsement by NIOSH.

Disclosure statement

The authors have no relevant information or relationships to disclose.

Additional information

Funding

This study was supported by internal operating funds of the U.S. National Personal Protective Technology Laboratory.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.