The accuracy of a 2D video-based lifting monitor

, , & ORCID Icon
Pages 1043-1054 | Received 07 Jan 2019, Accepted 07 May 2019, Published online: 28 May 2019
 

Abstract

A widely used risk prediction tool, the revised NIOSH lifting equation (RNLE), provides the recommended weight limit (RWL), but is limited by analyst subjectivity, experience, and resources. This paper describes a robust, non-intrusive, straightforward approach to automatically extract spatial and temporal factors necessary for the RNLE using a single video camera in the sagittal plane. The participant’s silhouette is segmented by motion information and the novel use of a ghosting effect provides accurate detection of lifting instances, and hand and feet location prediction. Laboratory tests using 6 participants, each performing 36 lifts, showed that a nominal 640 pixel × 480 pixel 2D video, in comparison to 3D motion capture, provided RWL estimations within 0.2 kg (SD = 1.0 kg). The linear regression between the video and 3D tracking RWL was R2 = 0.96 (slope = 1.0, intercept = 0.2 kg). Since low definition video was used in order to synchronise with motion capture, better performance is anticipated using high definition video.

Practitioner's summary: An algorithm for automatically calculating the revised NIOSH lifting equation using a single video camera was evaluated in comparison to laboratory 3D motion capture. The results indicate that this method has suitable accuracy for practical use and may be, particularly, useful when multiple lifts are evaluated.

Abbreviations: 2D: Two-dimensional; 3D: Three-dimensional; ACGIH: American Conference of Governmental Industrial Hygienists; AM: asymmetric multiplier; BOL: beginning of lift; CM: coupling multiplier; DM: distance multiplier; EOL: end of lift; FIRWL: frequency independent recommended weight limit; FM: frequency multiplier; H: horizontal distance; HM: horizontal multiplier; IMU: inertial measurement unit; ISO: International Organization for Standardization; LC: load constant; NIOSH: National Institute for Occupational Safety and Health; RGB: red, green, blue; RGB-D: red, green, blue – depth; RNLE: revised NIOSH lifting equation; RWL: recommended weight limit; SD: standard deviation; TLV: threshold limit value; VM: vertical multiplier; V: vertical distance

Acknowledgements

The findings and conclusions in this paper are those of the author(s) and do not necessarily represent the official position of the National Institute for Occupational Safety and Health, Centres for Disease Control and Prevention.

Additional information

Funding

Funding for this publication was made possible (in part) by grants from the National Institute for Occupational Safety and Health (NIOSH/CDC), [R01OH011024] (Radwin).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.