Abstract
A newly developed expression for the mean time to failure, MTTF k/n , of a non-repairable k-out-of-n : G identical unit system with warm standby and common-cause failures is presented. A modified version of this formula, (which takes into consideration the repairability of the warm stand-by) and the system reliability and variance of time-to-failure expressions for some special cases, are also reported.