0
Views
0
CrossRef citations to date
0
Altmetric
Original Articles

Industrial Radiography with Phosphor Screens

Pages 217-226 | Received 04 Jun 1981, Published online: 21 Jul 2016
 

Abstract

An experimental system that comprises a film of low silver content and a pair of high resolution phosphor intensifying screens and a commercial industrial X-ray film of similar speed arc compared for image quality. The speed of the radiographic systems and the X-ray energy of 200 kV that are fundamental to this study are both of particular interest to the industrial radiographer. The image quality is assessed by use of data derived from microdensitometer traces of a line test object, which provides information on the image contrast and on the grainincss, and by use of prints of magnified radiographs. It is concluded that the use of phosphor screens offers an increase in image quality when the information is limited by the graininess or quantum mottle of a radiograph which is frequently the case in practical radiography.

Résumé

La qualité des images fournies par un système expérimental comportant un film à faible teneur en argent et deux écrans renforçateurs fluorescents est comparée à celle des images obtenues avec un film commercial pour radiographie industrielle de même sensibilité. La sensibilité des systèmes radiographiques et l’énergie des rayons X (200kV), qui sont des données fondamentales pour cette étude, sont toutes deux particulièrement intéressantes pour les radiologistes. La qualité de l’image est évaluée à partir de résultats déduits du tracé microdensitométrique d’une ligne objet test qui fournit des informations sur le contraste et la finesse de grain de l’image et à partir de tirages des radiogrammes agrandis. On en conclut que l’emploi d’écrans fluorescents permet d’accroitre la qualité de l’image lorsque l’information est limitée par la finesse de grain ou par la granulation quantique du radiogramme, ce qui est fréquemment le cas en radiographie.

Zusammenfassung

Ein experimentelles System bestehend aus einem Film mit niedrigem Halogensilberauftrag zwischen zwei hochauflösenden Phosphor-Verstärkerschirmen wurde hinsichtlich Bildqualität mit einen industriellen Röntgenfilm von ähnlicher Empfindlichkeit verlichen. Die Empfindlichkeit der Materialien und die Röntgenstrahlenergie von 200keV lagen in dem für die Praxis interessanten Bereich Die Bildqualität wurde a tlS mikrodensitometrischen Ausmessungen der Aufnahmen eines linienförmigen Testobjektes bestimmt, welche Informationen über Kontrast und Körnigkeit lieferten, und zusätzlich aus der Beurteilung von vergrösserten Kopien der radiografischen Aufnahmen. Die Verwendung der Phosphor-Schirme führte zu einer Verbesserung der Bildqualität in den Fällen, wo die Information durch die Körnigkeit des Materials oder durch das Quantenrauschen begrenzt wird, was bei der praktischen Radiografie häufig vorkommt.

Riassunto

Sono state confrontate la qualità di immagine di un sistema sperimentale costituito da un film a basso contenuto in argento ed una coppia di schermi intensificatori con fosforo di elevata risoluzione, con quelle di un film commerciale per radiografia industriale a raggi X di sensibilità equivalente.

La sensibilità dei sistemi radiografici e l’energia a raggi X di 200 kV, che sono fondamentali in questo studio, sono entrambi di particolare interesse per il radiologo industriale.

La qualità di immagine è stata stabilita usando i dati ottenuti dalle tracce microdensitometriche di un campione a linee, che fornisce informazioni sul contrasto dell’immagine e sulla granulazione, e da stampe della radiografie ingrandite. Si è concluso che l’uso di schermi al fosforo fornisce un miglioramento della qualità di immagine quando l’informazione viene limitata dalla granulazione o dalle disuniformità quantiche, come accade frequentemente nella radiografia pratica.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.