53
Views
2
CrossRef citations to date
0
Altmetric
ORIGINAL ARTICLE

Imprecision of cardiac marker analyses among laboratories on the basis of external quality assurance results: Finnish experience

, , , , , & show all
Pages 507-518 | Received 03 Apr 2006, Accepted 07 Dec 2006, Published online: 08 Jul 2009
 

Abstract

The purpose of this report was to evaluate the reproducibility and harmonization of cardiac marker tests and to describe the current situation concerning quality of assays for cardiac markers on the basis of the results of the external quality control schemes (EQAS) of Labquality Ltd., Helsinki, Finland in the period 2002 to 2005. Finnish EQAS surveys obtained for proficiency samples at low marker concentration indicated that the overall coefficient of variation (CV) between laboratories for CK‐MBmass and troponin I exceeded 10 %, while for cardiac troponin T the CV was 8.6 %. Intra‐laboratory reproducibility was investigated in a single laboratory using concomitant testing in the same EDTA plasma samples to establish cut‐off limits for one CK‐MBmass and three troponin assays. The 10 % imprecision limit obtained from the concomitant testing in the same samples for CK‐MBmass was (by Elecsys®) 8.5 µg/L, for cardiac troponin T (by Elecsys®) 0.023 µg/L and for cardiac troponin I (by AxSYM® and by Immulite® 2000) 0.85 µg/L and 0.63 µg/L. At present, it is recommended that laboratories determine the concentration at which the 10 % imprecision for a specific cardiac marker assay is reached, because the assays generally do not reach that imprecision at the level of the 99th percentile value, usually taken as decisional level. However, common efforts of scientific societies and professional diagnostic industry associations internationally are needed if consensus is to be reached on standardization of immunoassays for cardiac markers and uniform results obtained among laboratories.

Acknowledgements

We thank Labquality Ltd. for putting the results of cardiac marker proficiency testing at our disposal. We also thank special laboratory technician Tero Hongisto for preparing the serum samples for the surveys and Jouni Sallinen of Abbott Finland and Hannu Eloranta of DPC Finland for fruitful collaboration.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.