395
Views
13
CrossRef citations to date
0
Altmetric
Original Articles

Stability of complete blood count parameters depends on the storage temperature, storage time, transport position and selected stability criterion

, &
Pages 470-478 | Received 23 Dec 2019, Accepted 13 Jun 2020, Published online: 28 Jun 2020
 

Abstract

Purpose: To evaluate stability of CBC parameters in samples containing K3-EDTA in Hema&Tube brand evacuated tubes stored at 4 °C and room temperature in upright, horizontal and upside-down transport positions for up to 240 min by comparing with different stability criteria. Methods: A total of 450 outpatient samples, 75 for each condition, were stored for 240 min. Blood samples were analyzed at baseline, 60th, 120th and 240th min of storage time using Sysmex® XT-4000i hematology analyzer. CBC results were compared according to the paired samples t-test, one CV% change, CVI, BV DES 2014, RCPA, IQMH, EFLM Biological Variation 2019, ESfEQAand CLIA stability criteria. Results: In all transport conditions, almost all CBC parameters were unstable according to the paired samples t-test. Based on one CV % change RBC, hemoglobin, hematocrit, RDW-CV, neutrophils, platelets, MPV, PDW and plateletcrit were unstable in some transport conditions. However, most parameters were stable at all conditions, except especially for MCH, MPV, PDW and plateletcrit, while just MPV and PDW were unstable at RT in all transport conditions according to the lower and higher CVI, respectively. Conclusions: Paired samples t-test and one CV% change stability criteria are not suitable for decision. Clinical laboratories should establish the impact of storage time, storage temperature and transport positions for each CBC parameter while paying attention to the brand of evacuated tube according to the lower CVI of biological variation data stability criteria since it is more related to the impact of analysis deviation on clinical decisions to prevent misdiagnosis.

Acknowledgements

The authors thank all laboratory technicians in Hematology Laboratory of Erol Olcok Education and Research Hospital for their technical support.

Disclosure statement

The authors declare that this research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.