Prevalence of iron deficiency anemia and iron deficiency in a pediatric population with inflammatory bowel disease

, &
Pages 1099-1103 | Received 21 Jan 2017, Accepted 07 Jun 2017, Published online: 23 Jun 2017
 

Abstract

Objectives: Iron deficiency is the most common cause of anemia in children with inflammatory bowel disease, although the real prevalence is unknown. Intravenous iron is suggested as the first line treatment. This study aims to determine the prevalence of iron deficiency anemia in children with inflammatory bowel disease followed in a Pediatric Gastroenterology Unit of a tertiary center and to evaluate this unit's experience with intravenous iron.

Materials and methods: A retrospective cohort study was designed involving children with inflammatory bowel disease followed in that unit between January 2001 and April 2016. Laboratory results were collected at the moment of diagnosis, after one-year follow-up and prior each IV iron administration performed during the study period. Anemia was defined according to World Health Organization criteria and the iron deficiency was defined using recent guidelines.

Results: Were studied 69 patients 71% had CD and 29% UC. 50.7% were female. Mean patient age at diagnosis was 13.3 years (range 1--17 years). Prevalence of ID and IDA at diagnosis was 76.8% and 43.5%, respectively. After one year follow-up, those values decreased to 68.1% (p = .182) and 21.7% (p = .002), respectively. Hemoglobin significantly increased (p < .001). Intravenous iron was administered to 92.8% of patients. No adverse reactions were reported.

Conclusions: Intravenous iron is the first line in the treatment of Iron deficiency anemia in Inflammatory Bowel disease and it is safe and effective. Persistent anemia and iron deficiency are common.

View correction statement:
Correction to: Carvalho et al., Prevalence of iron deficiency anemia and iron deficiency in a pediatric population with inflammatory bowel disease

Disclosure statement

The authors report no conflicts of interest.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.