644
Views
7
CrossRef citations to date
0
Altmetric
Original Research or Treatment Papers

Removal of Organic Acids from Indoor Air in Museum Storage Rooms by Active and Passive Sorption Techniques

ORCID Icon, ORCID Icon & ORCID Icon
Pages 251-261 | Received 29 Jan 2020, Accepted 06 Apr 2020, Published online: 24 Apr 2020
 

ABSTRACT

Adsorbent materials can be used for the removal of organic acids from air in storage rooms with heritage collections. The organic acid removal efficiency of two commercially available activated carbon air-filters were tested in situ in two unoccupied stores with densely packed collections. One filter was designed for outdoor type pollutants (Filter A), while the other was designed for organic acids in indoor air (Filter B). Furthermore, the acetic acid removal efficiency of a desiccant silica gel rotor used for dehumidification was measured in a laboratory at different relative humidity levels. Finally, passive removal of acetic acid by silica gel and unfired clay brick were tested in a chamber, and for clay brick at room level as well. Filter B had the highest removal efficiency. The removal efficiency of both filter types depended on the airflow and the filter performance varied considerably in situ from the values reported from standard laboratory tests. Increasing the filter airflow reduced the removal efficiency from 77% and down to 7% for Filter A, and from 92% to 24% for Filter B. There was almost no effect of active air filtration on the concentration of organic acids when this was measured in the middle and in the corner of the storage rooms away from the ventilation inlets. The desiccant dehumidifier removed 98–100% of the acetic acid from the air, independently of the relative humidity. The desiccant rotor will, however, only be running when there is a need for dehumidification and as a result will only periodically remove pollutants. The high acid removal efficiency by dry silica gel was furthermore demonstrated in a chamber test. A clay brick wall in a test room established a concentration gradient across the room and reduced the concentration of organic acids by 56% compared to close to the emission source.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Data availability statement

All data generated during this study are included in this published article.

Additional information

Funding

This work was supported by the Independent Research Fund Denmark grant number: DFF-6121-00003.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.