241
Views
4
CrossRef citations to date
0
Altmetric
Original Articles

The influence of Body Roundness Index on sensorial block level of spinal anaesthesia for elective caesarean section: an observational study

ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon, ORCID Icon & ORCID Icon
 

Abstract

In this prospective trial, we investigate the effectiveness of maternal Body Roundness Index in predicting the spread of spinal anaesthesia and vasopressor requirement in parturients receiving spinal anaesthesia during the elective caesarean section. We prospectively enrolled 175 parturients. Spinal anaesthesia performed with 10 mg 0.5% hyperbaric bupivacaine at the L3–L4 intervertebral space and the optimal cut-off points of the BRI evaluated as 6.59 by receiver operating characteristic analysis calculating area under the curve. Parturients were divided into two groups with BRI <6.59 and BRI ≥6.59 for analyses. Multivariate logistic regression analysis was used to test for a relationship between variables and maximum sensory block level and vasopressor requirement. BRI was found as an independent risk factor associated with maximum sensory block level (OR = 1.378, 95% CI: 1.125–1.687, p = 0.002). Hypotension and bradycardia events after spinal anaesthesia was not associated with BRI and other variables. The present study indicates that BRI was a practical tool to predict spinal drug distribution in term parturients undergoing caesarean delivery.

    Impact statement

  • What is already known on this subject? Spinal anaesthesia is a commonly used anaesthetic technique for the caesarean section. However, the spinal drug distribution is highly unpredictable. Anthropometric variables may predict the intrathecal drug distribution in parturients. Body Roundness Index (BRI) captures body circumference regarding height to predict body fat percentage, consider the shape of the human body as an ellipse. An ellipsoid body shape might affect the spread of spinal anaesthesia.

  • What do the results of this study add? Our results show that the BRI was as an independent risk factor associated with maximum sensory block level in term parturients undergoing caesarean delivery.

  • What are the implications of these findings for future clinical practice and/or further research? A future study would present the possibility to design a formula for the exact amount of local anaesthetic to be used in spinal anaesthesia with the aid of maternal BRI.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Disclosure statement

The authors reported no potential conflict of interest

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.