Research on the Use of Heat Pipe Heat Exchanger in Installation for Heat Treatment of Aqueous Kaolin Suspension

&
 

Abstract

This paper contains an analysis of the process carried out in a heating system for the treatment of aqueous kaolin suspension in order to identify the causes of cyclical, relatively frequent loss of system functionality. The analysis showed that the main cause of the short usability time of the installation is the inappropriateness of the heat exchangers' construction for the implemented technology, while the physical and chemical parameters and the rheological properties of kaolin suspensions are of secondary importance. It is proposed to replace the plate heat exchangers used in the installation with heat pipe exchangers of special construction. The results of laboratory and experimental tests of a heat pipe exchanger designed specifically for the described application are presented. An empirical comparison of the effectiveness of the proposed heat exchanger with a double pipe exchanger was performed by conducting tests in the process conditions of genuine installations and using the method of ϵ–NTU for efficiency calculations.

NOMENCLATURE

A=

heat transfer area of double pipe heat exchanger, m2

C=

concentration,% m/m (percent by mass)

cp=

specific heat at constant pressure, J kg−1 K−1

D=

internal pipe diameter, m

Dz=

external pipe diameter, m

F=

heat transfer area of heat pipe heat exchanger, m2

K=

fluid consistency index, Pa sn

K'=

apparent fluid consistency index, Pa sn'

L=

length of exchanger, m

=

mass flow rate, kg s−1

n=

flow behavior index, dimensionless

n'=

apparent flow behavior index, dimensionless

NTU=

number of transfer units, dimensionless

=

heat transfer rate (heat “duty”), W

R=

correlation coefficient, dimensionless

R2=

determination coefficient, dimensionless

ReMR=

Metzner and Reed Reynolds number, dimensionless

TM=

methanol temperature, K

T=

temperature, K

U=

overall heat transfer coefficient, W m−2 K−1

=

volumetric flow rate, m3 s−1

v=

linear velocity, m s−1

W=

heat capacity rate, W K−1

Greek Symbols

α=

significance coefficient, dimensionless

ΔTm=

logarithmic average temperature difference, K

δ=

pipe wall thickness, m

ϵ=

thermal efficiency of heat exchanger, dimensionless

ηh=

temperature efficiency of the hot fluid, dimensionless

ρ=

density, kg m−3

Subscripts

c=

cold fluid (heat-receiving fluid)

con=

condensation zone

DP=

double pipe

ev=

evaporation zone

h=

hot fluid (heat-releasing fluid)

HP=

heat pipe

p=

pasteurization

s=

suspension

Superscripts

in=

inlet

out=

outlet

Additional information

Notes on contributors

Halina Marczak

Halina Marczak is an assistant professor in the Department of Safety, Process Engineering, and Ecology in Lublin University of Technology, Lublin, Poland. She received her Ph.D. in mechanics and machinery construction from the Lublin University of Technology, Lublin, Poland. She is currently working on enhanced heat transfer in heat exchangers.

Lech Hys

Lech Hys is an assistant professor in the Department of Safety, Process Engineering, and Ecology in Lublin University of Technology, Lublin, Poland. He received his Ph.D. in mechanics and machinery construction from the Lublin University of Technology, Lublin, Poland. He is currently working on enhanced heat transfer in heat exchangers.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.