Abstract
A high performance liquid chromatographic (HPLC) technique has been developed for the determination of bupropion hydrocloride (Bup) in human plasma, using a reversed-phase method, with UV detection at 250 nm.
The internal standard 5-(P-methylphenyl)-5-phenylhydantoin (MPPH), was used as an aid to quantitation. The plasma was deprotemized with acetonitrile and the clear supernatant was directly injected in the chromatographic system. The lower limit of quantitation was 5.0 ng/ml using only 100 μl of plasma sample.
Linear regression analysis for the calibration plots obtained on five different days over a two-week period for the the two ranges used (10–250 ng/ml and 250–2000 ng/ml) in plasma indicated excellent linearity and reproducibility. The mean recovery of spiked Bup in plasma samples over the concentrations studied was found 96.5 ± 3.14%.
The method revealed that more than 30% of Bup was lost when the supernatant was stored at room temperature for 24 hrs.