14
Views
20
CrossRef citations to date
0
Altmetric
Original Articles

Rapid Assay For the Simultaneous Determination of Residues of Oxolinic Acid and Flumequine in Fish Tissues by High-Performance Liquid Chromatography

, &
Pages 61-70 | Published online: 23 Oct 2006
 

Abstract

A simple and rapid method for the simultaneous extraction and determination of residues of oxolinic acid (OX) and flumequine (FQ) in fish tissue, muscle and liver, is presented. the samples were extracted with acetonitrile and ammonia. the drugs were then extracted into a water phase, acidified, and extracted with CHCI3. After evaporation, the sample was redissolved in mobile phase and filtered through a spin-X centrifuge filter. the filtrate was injected onto the HPLC. the calibration curves were linear, and the recovery of oxolinic acid was 101–104 % while the recovery of flumequine was 88–94 %. the detection limits were 5 ng/g for oxolinic acid and 10 ng/g for flumequine.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.