Abstract
A simplified mathematical model for determining the concentration of different components, including impurities, during the washing phase of an affinity ultrafiltration system is presented from a mechanistic approach. The results are compared with experimental data published in the literature. The good fit indicates that the model is closer to reality than those reported so far.