99
Views
6
CrossRef citations to date
0
Altmetric
Original Articles

Effect of the aspect ratio of the pre-existing rectangular adhesion failure on the structural integrity of the adhesively bonded single lap joint

ORCID Icon, &
Pages 2093-2111 | Received 14 Mar 2019, Accepted 31 May 2019, Published online: 26 Jun 2019
 

Abstract

Non-linear three dimensional (3-D) finite element analyses (FEA) of the single lap joints (SLJs) having pre-existing rectangular adhesion failure in the interface of the strap adherend and the adhesive have been carried out. The effect of the size, the shape and the aspect ratio of the pre-existing rectangular adhesion failure on (i) the strength, (ii) the interfacial stresses and (iii) the strain energy release rates (SERRs) in the vicinity of the adhesion failure front have been presented in this research work. The SLJ is subjected to uniformly applied tensile load. The adherends are made with very high strength steels and the adhesive is a commercially available AV119. The analyses of the adhesion failure propagation have been carried out by sequentially releasing the constraints of the nodes ahead of the pre-existing adhesion failure front in finite element model. The SERR values in the vicinity of the adhesion failure fronts are computed using the virtual crack closure technique (VCCT) for assessment of the structural integrity of the SLJ. The strength of the SLJ, the interfacial stresses, and the three modes of strain energy release rates (SERRs) have been found to be significantly affected by the shape and size of adhesion failures. The SERRs and interfacial stresses along the rectangular adhesion failure front are compared with the corresponding values around the circular adhesion failure front of same area, pre-existing in the SLJ. It is observed that the circular and rectangular adhesion failures of the same area will have dissimilar growth rate and the mode II is the dominant failure mode. The total strain energy release rate and the failure strength, computed from the 3-D FEA of the SLJ is in good agreement with the experimental fracture toughness of the AV119 adhesive and the experimentally obtained failure loads, respectively.

Disclosure statement

No potential conflict of interest was reported by the authors.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.