Biological adhesion and electrochemical behavior of Ag-ZrO2 bioceramic coatings for biomedical applications

, , , &
Pages 349-368 | Received 10 Feb 2019, Accepted 05 Sep 2019, Published online: 23 Sep 2019
 

Abstract

Recently, surface tailoring of the metallic implant has taken considerable attention to enhance the longevity of implants. In this study, two different concentrations of silver (Ag) with zirconia (ZrO2) were deposited onto titanium (Ti) substrates using DC magnetron sputtering for both orthopedic and dental implants application. Thickness, surface morphology with elemental composition, functional group, and adhesion of the coatings were characterized by X–ray diffraction (XRD), stylus profilometer, field-emission scanning electron microscopy/energy-dispersive X-ray spectroscopy (FESEM/EDAX), Fourier transform infrared spectroscopy (FTIR) and nano-scratch indentor, respectively. Monoclinic phase of ZrO2 and cubic phase of Ag were confirmed with XRD. Nanostructured grains were obtained by FESEM analysis with the thickness of ∼300 nm, ∼700 nm and ∼800 nm for ZrO2, ZrO2–Ag and ZrO2–Ag(1) (Herein, ZrO2–Ag (low conc.) and ZrO2–Ag(1) (high conc.) coatings measured by profilometer. The in vitro bacterial adhesion was performed for as prepared ZrO2, ZrO2–Ag and ZrO2–Ag(1) coatings against E.coli, and Streptococcus sp. Adhesion study exhibits better performance for Ag containing ZrO2 rather than ZrO2 coated and uncoated Ti. Adhesion of platelet on the coated and uncoated Ti revealed that activated platelets are present in ZrO2–Ag(1) coated Ti. ZrO2 and ZrO2–Ag coated Ti showed enhanced fibroblast cell attachment and proliferation than uncoated Ti but not in ZrO2–Ag(1) coated Ti surface. Electrochemical impedance spectroscopy (EIS) results revealed superior corrosion resistance behavior for all the coatings than uncoated Ti in ABP electrolyte. The results stated those tailored Ti surfaces were certainly used to enhance the durability of the implant for biomedical applications.

Disclosure statement

No potential conflict of interest was reported by the authors.

Additional information

Funding

Financial support from Department of Biotechnology (BT/PR14718/MED/32/434/2015), New Delhi, India is greatly acknowledged.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.