The Oxidation of Manganese and Disinfection By Ozonation in Water Purification Processing

Pages 623-637 | Published online: 17 Oct 2012
 

Abstract

The surface water of a river has been used as the raw water by the Waterworks Bureau of Osaka City. At present, the manganese contained in the raw water is oxidized by breakpoint chlorination and all oxides are removed by coagulation, sedimentation followed by rapid sand filtration, with chlorine being used as the final disinfectant.

Prechlorination was not conducted in the ongoing pilotplant experiment of an advanced water purification process with ozone and granular activated carbon. It is necessary, therefore, to oxidize manganese by the oxidative effect of ozone instead of prechlorination.

It is important for the treatment of manganese to adjust the ozone dosage because manganese is oxidized up to the soluble septavalent state by the surplus ozone. Since ozone does not continue to exist for very long in water, though its disinfecting power is high, final disinfection by chlorine is required.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.