Technical developments for cerebral thermal treatment: water-cooled diffusing laser fibre tips and temperature-sensitive MRI using intersecting image planes

, , , , &
Pages 45-56 | Received 31 Jan 2003, Accepted 24 Jun 2003, Published online: 09 Jul 2009
 

Abstract

The aim was to determine if water-cooled diffusing tips could produce larger and safer (better controlled) thermal lesions than non-cooled diffusing tips at 980 nm. Thermal lesions were induced in beef myocardium in vitro with and without water cooling using a 980 nm diode laser at various power levels. Seven intracerebral treatments were performed in six canines using water-cooled diffusing tips with four animals having intracerebral transmissible venereal tumours grown from inoculate. Magnetic resonance thermal imaging (MRTI)-based feedback software using a fast, radio frequency-spoiled gradient echo acquisition with two intersecting image planes was used for on-line monitoring and control of treatment and for the evaluation of in vivo laser lesion production. In cases where two-plane MRTI was employed, the maximum calculated temperature was compared in each plane. Using water-cooled tips and 400 µm core diameter laser diffusing fibres in in vitro beef myocardium, power of up to 9.5 W was applied for 8 min without tip failure. Without cooling, tip failure occurred in under 4 min at 6 W, in under 2 min at 7 W and instantaneously at 8 W. Additionally, char accompanied lesions made with uncooled tips while cooled application resulted in only minimal char at only the highest thermal dose. Achieved lesion cross-sectional diameters in in vitro samples were up to 26.5 × 23.3 mm when water cooling was used. In canine brain and transmissible venereal tumours, up to 18.1 × 21.4 mm lesions were achieved. It is concluded that water cooling allows safe application of higher power to small core diameter diffusing tip fibres, which results in larger thermal lesions than can be achieved without cooling. Two-plane MRTI enhances on-line monitoring and feedback of thermal treatment.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.