130
Views
0
CrossRef citations to date
0
Altmetric
Research Article

Feasibility, safety and efficacy of high intensity focused ultrasound ablation as a preoperative treatment for challenging hysteroscopic myomectomy

, , , , , , , , , , & show all
Article: 2365974 | Received 12 Dec 2023, Accepted 05 Jun 2024, Published online: 16 Jun 2024
 

Abstract

Purpose

To investigate the feasibility, safety and efficacy of high intensity focused ultrasound ablation (HIFU) as a preoperative treatment for challenging hysteroscopic myomectomies.

Materials and methods

A total of 75 patients diagnosed with types 0–III of uterine fibroids were enrolled. Based on the Size, Topography, Extension of the base, Penetration and lateral Wall position (STEPW) classification scoring system, 25 cases with a score ≥ 5 points were treated with HIFU followed by hysteroscopic myomectomy (HIFU + HM group), whereas 50 cases with a score < 5 points were treated with hysteroscopic myomectomy (HM group).

Results

The median preoperative STEPW score was 7 in the HIFU + HM group and 2 in the HM group. The average non-perfused volume (NPV) ratio achieved in fibroids after HIFU was 86.87%. Patients in the HIFU + HM group underwent hysteroscopic myomectomy one to four days after HIFU, and downgrading was observed in 81.81% of fibroids. The operation time for patients in the HIFU + HM group was 73 min and the success rate of myomectomy in a single attempt was 60%. The volume of distention medium used during the operation was greater in the HIFU + HM group than in the HM group (15,500 ml vs. 7500 ml). No significant difference was observed between the two groups in terms of intraoperative blood loss, the incidence of intraoperative and postoperative complications, menstrual volume score, or uterine fibroid quality of life score.

Conclusion

HIFU can be utilized as a preoperative treatment for large submucosal fibroids prior to hysteroscopic myomectomy. HIFU offers a novel approach in the management of this subset of patients.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Data availability statement

The data that support the findings of this study are available upon request from the corresponding author, TTL. The data are not publicly available because it contains information that can compromise the privacy of the research participants.

Additional information

Funding

This study was supported by the Foundation of State Key Laboratory of Ultrasound in Medicine and Engineering (Grant No. 2021KFKT012) and the Scientific Research Projects of Sichuan Maternal and Child Health Association (Grant No. 21FX018).