The safe use of long screws in L5/S1 stand-alone anterior interbody fusion for olisthesis cases

, , &
Pages 28-31 | Received 13 Nov 2017, Accepted 19 Jan 2018, Published online: 06 Feb 2018
 

Abstract

Background: Stand-alone anterior interbody fusion (STALIF) with poly-ether-ether-ketone (PEEK) cages could offer a treatment option in olisthesis cases. The fixation of the PEEK-cage at the L5/S1 inferior endplate with long divergent screws however might endanger neural sacral structures, especially the S1 nerve root. If shorter screws are used, the achieved bony purchase might not be sufficient to resist the pull out and shear forces at the lumbosacral junction. The aim of the present investigation was to evaluate the use of long screws in PEEK-cages for olisthesis cases at the L5/S1 segment and its neurological complications.

Material and methods: 11 Patients (6 males) with a mean age of 47(± 15.1) years between 2013–2015 designated for an STALIF at the L5/S1 level were consecutively included in the present study. All patients had a Grade 1 or 2 slippage according to Meyerding. PEEK cages (SynFix-LR®, Depuy Synthes) were implanted with 30mm screws at the baseplate of L5/S1 in all patients. Perioperative and postoperative long-term complications were evaluated. Furthermore, radiological follow-up was performed (CT-scan at 6 months, X-ray at 6, 12 and 24 months).

Results: 6 patients suffered from an isthmic, 1 from a degenerative olisthesis. 4 patients with iatrogenic spondylolisthesis were included. Pre-operative radiculopathy was noted in 10 patients. 9 patients with pre-operative radiculopathy showed relief of symptoms until the last follow-up after 24 months. Fusion was achieved in all patients after 6 months. No screw-displacement, breakage or violation of the neural foramen was noted. Furthermore, no implant failure or pull-out fractures were seen.

Conclusion: In this investigation, no complication due to the use of long divergent locking screws was noted. In addition, the majority of patients showed permanent relief of radiculopathy symptoms at the 2 years follow-up. This study demonstrates the safe usage of long divergent locking screws in the baseplate of L5/S1 in anterior interbody fusion at the L5/S1 level.

Disclosure statement

No benefits or funds in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.