173
Views
4
CrossRef citations to date
0
Altmetric
Retina

Efficacy of the Inverted Internal Limiting Membrane Flap Technique with Perfluorocarbon Liquid-Mediated Selective Staining for Large Macular Hole Repair

&
Pages 53-59 | Received 02 Jul 2018, Accepted 11 Sep 2018, Published online: 01 Oct 2018
 

ABSTRACT

Purpose: The aim of the present study was to evaluate the efficacy of the inverted internal limiting membrane (ILM) flap technique that involved the use of a perfluorocarbon liquid (PFCL) bubble for the selective prevention of indocyanine green (ICG) staining of the parts of the inverted flap in contact with the retinal pigment epithelium for large macular hole (MH) closure.

Materials and Methods: This retrospective, interventional, comparative study included 26 patients with idiopathic large MHs (minimum diameter, > 400 µm) who underwent vitrectomy using the inverted ILM flap technique with conventional ILM staining with ICG (n = 14, Group 1) or PFCL-mediated selective ILM staining with ICG (n = 12, Group 2). The hole closure rate, best-corrected visual acuity (BCVA), and optical coherence tomography findings were analyzed at baseline and 1, 3, and 6 months after surgery in both groups.

Results: Hole closure was achieved in all the eyes. BCVA significantly improved after surgery in both groups (p < 0.001 for both groups), although Group 2 exhibited significantly better values at 3 and 6 months after surgery (p = 0.008 and 0.001 at 3 and 6 months, respectively). The sizes of ellipsoid zone defect significantly decreased after surgery in both groups (p < 0.001 relative to the baseline width in both groups), and it was significantly smaller in Group 2 than in Group 1 at 3 (p = 0.006) and 6 (p = 0.001) months after surgery.

Conclusions: The findings of this study suggest that recovery of the photoreceptor layers and, consequently, the postoperative VA are better with the inverted ILM flap technique employing PFCL-mediated selective ILM staining with ICG than with the technique employing conventional ILM staining with ICG methods for patients with large MHs.

Acknowledgments

None.

Disclosure Statement

The authors report no conflicts of interest. The authors alone are responsible for the content and writing of the paper.

Compliance with Ethical Standards

Ethical Approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Additional information

Funding

None.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.