Retina

Ocular Blood Volume Index Based on Scattering Properties of Retinal Vessels Using Spectral Domain Optical Coherence Tomography

ORCID Icon, , &
Pages 60-66 | Received 22 Nov 2017, Accepted 11 Sep 2018, Published online: 15 Oct 2018
 

ABSTRACT

Introduction: The evaluation of retinal vessels and the retinal blood flow is important for ocular diseases. We introduce a spectral domain optical coherence tomography (SD-OCT) based method for facilitating a retinal blood vessel analysis using the scattering properties of retinal vessels. The intensity of the distal shadow of vessels caused by the scattered signal is measured, correlated with the pulsatile ocular blood flow (POBF), and its repeatability is analyzed.

Methods: About 20 eyes of 20 healthy, young participants (mean age 23.15 years, standard deviation 2.3 years) were included in the analysis. Participants underwent ophthalmic diagnostics including three repeated SD-OCT examinations and measurement of POBF. The vessel shadow intensity analysis is based on peripapillary SD-OCT scans and automatically analyses the intensity of the distal vessel shadow compared to its surroundings.

Results: The distal shadow of arteries in SD-OCT scans correlated with the POBF (r = 0.647, p = 0.002). Furthermore, the shadow intensity correlated with the established morphological arterio-venous ratio. The evaluation of repeatability was performed using the interclass correlation coefficient (ICC), showing good repeatability for individual vessels (ICC = 0.825) and arteries (ICC = 0.820).

Conclusions: In summary, we indicate that the scattering properties of retinal vessels in SD-OCT images might correlate with the vessel morphology and for retinal arteries with the retinal blood flow volume as well. Further studies are needed to establish this method’s sensitivity and specificity in participants with retinal and cardiovascular diseases.

Abbreviations

ART=

automatic real-time averaging mode

AV=

arterio-venous

CRAE-6=

central retinal artery equivalent

CRVE-6=

central retinal vein equivalent

cSLO=

confocal scanner laser ophthalmoscopy

ICC=

interclass correlation coefficient

IOP=

intraocular pressure

POBF=

pulsatile ocular blood flow

RNFL=

retinal nerve fiber layer

SD-OCT=

spectral domain optical coherence tomography

VSI=

vessel shadow intensity

Acknowledgments

None.

Disclosure Statement

Carsten Framme has received honoraria from Heidelberg Engineering.

No competing relationship exists for any other author.

The authors alone are responsible for the content and writing of the paper.

Additional information

Funding

None.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.