224
Views
2
CrossRef citations to date
0
Altmetric
Cornea

Toric Intraocular Lens Calculation Considering Anterior Surgically Induced Astigmatism and Posterior Corneal Astigmatism

, ORCID Icon, ORCID Icon, &
Pages 25-31 | Received 15 Feb 2021, Accepted 14 Jun 2021, Published online: 30 Jun 2021
 

ABSTRACT

Purpose

To evaluate the prediction error (PE) after applying the Abulafia–Koch formula in an online calculator with and without consideration of anterior corneal surgically induced astigmatism (SIACornea).

Methods

SIACornea models were calculated with a historical database of 204 right eyes (REs) from a single surgeon, either for manual (2.2 mm) or femtosecond (2.5 mm) temporal clear corneal incisions. PE was assessed in 58 REs operated by the same surgeon with a monofocal toric IOL and calculated, considering the PCA estimation in an online calculator with the combination of each one of the following SIACornea calculation approaches: (A) considering only significant centroids after stratification, (B) all centroids after stratification and (C) a single centroid without stratification.

Results

The consideration of all centroids resulted in an underestimation of SIACornea in cases of preoperative against-the-rule astigmatism (ATR-A) and an overestimation in with-the-rule astigmatism (WTR-A). After stratification, SIACornea was only significant in preoperative ATR and oblique astigmatism cases for femtosecond incisions. PE considering PCA only was 0.03@160º. The combination with SIACornea resulted in a WTR-A surprise in preoperative ATR-A and WTR-A, however only being significant for preoperative ATR-A in calculation approaches B (0.29@84º) and C (0.21@80º). SIACornea addition to PCA estimation only reduced the centroid for oblique preoperative astigmatism.

Conclusions

Surgeons should consider the calculation of the SIACornea after stratification by astigmatism type when using the same incision location (i.e. temporal). However, SIACornea derived from the anterior corneal surface should not be combined with PCA estimation for IOL power calculations.

Acknowledgments

The authors would like to thank the reviewers for their exceptional contributions to improve the first draft of this manuscript.

Disclosure statement

Dr. Fernández is consultant from Medicontur and Rodríguez-Vallejo M is the developer of the system used to calculate the surgically induced astigmatism and to measure visual acuity. The remaining authors have nothing to disclose.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.