247
Views
1
CrossRef citations to date
0
Altmetric
Retina

Cross-camera Performance of Deep Learning Algorithms to Diagnose Common Ophthalmic Diseases: A Comparative Study Highlighting Feasibility to Portable Fundus Camera Use

, , , , , , , & show all
Pages 857-863 | Received 22 Feb 2023, Accepted 14 May 2023, Published online: 29 May 2023
 

Abstract

Purpose

To compare the inter-camera performance and consistency of various deep learning (DL) diagnostic algorithms applied to fundus images taken from desktop Topcon and portable Optain cameras.

Methods

Participants over 18 years of age were enrolled between November 2021 and April 2022. Pair-wise fundus photographs from each patient were collected in a single visit; once by Topcon (used as the reference camera) and once by a portable Optain camera (the new target camera). These were analyzed by three previously validated DL models for the detection of diabetic retinopathy (DR), age-related macular degeneration (AMD), and glaucomatous optic neuropathy (GON). Ophthalmologists manually analyzed all fundus photos for the presence of DR and these were referred to as the ground truth. Sensitivity, specificity, the area under the curve (AUC) and agreement between cameras (estimated by Cohen’s weighted kappa, K) were the primary outcomes of this study.

Results

A total of 504 patients were recruited. After excluding 12 photographs with matching errors and 59 photographs with low quality, 906 pairs of Topcon-Optain fundus photos were available for algorithm assessment. Topcon and Optain cameras had excellent consistency (Κ=0.80) when applied to the referable DR algorithm, while AMD had moderate consistency (Κ=0.41) and GON had poor consistency (Κ=0.32). For the DR model, Topcon and Optain achieved a sensitivity of 97.70% and 97.67% and a specificity of 97.92% and 97.93%, respectively. There was no significant difference between the two camera models (McNemar’s test: x2=0.08, p = .78).

Conclusion

Topcon and Optain cameras had excellent consistency for detecting referable DR, albeit performances for detecting AMD and GON models were unsatisfactory. This study highlights the methods of using pair-wise images to evaluate DL models between reference and new fundus cameras.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Data availability statement

All data relevant to this manuscript will be available upon acceptance.

Additional information

Funding

The present work was supported by Fundamental Research Funds of the State Key Laboratory of Ophthalmology, National Natural Science Foundation of China (82101173, 81870663, 82171075).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.