Issues in the Quantitation of Functional Groups by FTIR Spectroscopic Analysis of Impactor-Collected Aerosol Samples

Pages 899-908 | Published online: 30 Nov 2010
 

Fourier Transform Infrared (FTIR) spectroscopy is used to complement total carbon and molecular level measurements in the study of organic particulate matter because it is a relatively simple analytical procedure that provides chemically useful details (i.e., functional group and bond information) missing in total carbon measurements. FTIR characterizes the entire aerosol, whereas molecular methods identify only a small fraction of the organic mass. The need to measure the size-resolved chemical composition of ambient aerosols often necessitates the collection of aerosol samples with a single-jet impactor, such as a Hering low pressure impactor (LPI). Single-jet impactor samples have a nonuniform (conical) deposit geometry that results in a variable and inconsistent path length across the sample deposit and may also result in the enhancement of infrared beam scattering. This makes quantitation of LPI samples by traditional procedures based on Beer's Law impossible. Therefore we applied a ratio method developed by Cliff and Lorimer (1972) for energy dispersive spectroscopy to FTIR analyses of LPI samples. In this study the prospects and limitations for quantitative measurement of functional groups by FTIR spectroscopic analysis of impactor-collected aerosol samples is examined using laboratory-generated standards and size-segregated samples collected with a LPI in the Smoky Mountains. FTIR spectroscopy provides semiquantitative estimates of functional group concentrations (precision ∼50%) in aerosol samples. However, Infrared (IR) beam scattering due to the physical geometry of impactor deposits is a significant source of uncertainty, and concentrations of some functional groups appear to be substantially underestimated due to the "clipping" of high wave number IR peaks by rising baselines. The rising baselines result from increases in IR beam scattering with wave number and are related to the sample deposit geometry. Future sampling or analytical methodologies must overcome the bias that results from irregular sample deposit geometry.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.