113
Views
6
CrossRef citations to date
0
Altmetric
Original Articles

Application of Ni(II)-imprinted cross-linked poly(methacrylic acid) synthesised through double-imprinting method for the on-line preconcentration of Ni(II) ions in aqueous media

, , , &
Pages 1061-1071 | Received 10 Aug 2013, Accepted 31 Jan 2014, Published online: 05 Mar 2014
 

Abstract

The present paper describes the feasibility of on-line preconcentration of nickel ions from aqueous medium on Ni(II)-imprinted cross-linked poly(methacrylic acid) (IIP) synthesised through a double-imprinting method and their subsequent determination by FAAS. The proposed method consisted in loading the sample (20.0 mL, pH 7.25) through a mini-column packed with 50 mg of the IIP for 2 min. The elution step was performed with 1.0 mol L−1 HNO3 at a flow rate of 7.0 mL min−1. The following parameters were obtained: quantification limit (QL) – 3.74 µg L−1, preconcentration factor (PF) – 36, consumption index (CI) – 0.55 mL, concentration efficiency (CE) – 18 min−1, and sample throughput – 25 h−1. The precision of the procedure assessed in terms of repeatability for ten determinations was 5.6% and 2.5% for respective concentrations of 5.0 and 110.0 µg L−1. Moreover, the analytical curve was obtained in the range of 5.0–180.0 µg L−1 (r = 0.9973), and a 1.64-fold increase in the method sensitivity was observed when compared with the analytical curve constructed for the NIP (non-imprinted polymer), thus suggesting a synergistic effect of the Ni(II) ions and CTAB on the adsorption properties of the IIP. The practical application of the adsorbent was evaluated from an analysis of tap, mineral, lake and river water. Considering the results of addition and recovery experiments (90.2–100 %), the efficiency of this adsorbent can be ensured for the interference-free preconcentration of the Ni(II) ions.

Acknowledgements

The authors are grateful to the CNPq (Conselho Nacional de Desenvolvimento Científico e Tecnológico), the CAPES (Coordenação de Aperfeiçoamento de Pessoal de Nível Superior), the INCT for Bioanalytics (Instituto Nacional de Ciência e Tecnologia de Bioanalítica) and Fundação Araucária do Paraná for their financial support and fellowships.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.