Preconcentration and separation of Cd(II), Co(II), Cu(II), Ni(II), and Pb(II) in environmental samples on cellulose nitrate membrane filter prior to their flame atomic absorption spectroscopy determinations

, , , , &
Pages 364-377 | Received 05 Oct 2020, Accepted 21 Nov 2020, Published online: 17 Dec 2020
 

ABSTRACT

A new and sensitive enrichment membrane filtration method was applied for the preconcentration and separation of trace amounts of Cd(II), Co(II), Cu(II), Ni(II), and Pb(II) ions from environmental (water and food) samples prior to their flame atomic absorption spectrometric (FAAS) determinations. The method was based on the collection of analyte ions as quinalizarin complexes on cellulose nitrate membrane filter and then eluted using nitric acid. The concentration levels of Cd(II), Co(II), Cu(II), Ni(II), and Pb(II) ions in the final solutions were determined by FAAS. Various analytical parameters which affect the collection and determination of metal ions including pH, amounts of quinalizarin, sample volume, type and size of the membrane filter, flow rates and matrix effects were investigated. The analyte ions recovery values were measured and found to be in the range of 95–101%. The relative standard deviation (RSD%) was measured to determine the precision of the proposed approach and was found to be ≤5.0%. The detection limits for the proposed method were in the range of 0.1–0.7 μg L−1. The preconcentration factors were 100 and 125 for (Cd(II), Co(II), Cu(II) and Ni(II)) and Pb(II), respectively. The validation of the proposed method was verified by the analysis of certified reference materials. Satisfactory results for separation and preconcentration trace levels of the analyte ions in water and food samples.

Highlights

  • A new and sensitive enrichment membrane filtration method of some metals has been developed.

  • The final experimental conditions were studied and optimized.

  • The limits of detection were in the range of 0.1–0.7 μg L−1.

  • The proposed method was applied to determination of Cd(II), Co(II), Cu(II), Ni(II) and Pb(II) ions in water and food samples.

  • The validation of the method was tested by analysis of certified reference materials.

Acknowledgments

Authors would like to thank the Deanship of Scientific Research at Umm Al-Qura University for supporting this work by (Grant Code: 19-SCI-1-01-0023).

Disclosure statement

No potential conflict of interest was reported by the author(s).

Additional information

Funding

This work was supported by the Deanship of Scientific Research at Umm Al-Qura University [19-SCI-1-01-0023].

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.