Cuff-less and continuous blood pressure measurement based on pulse transit time from carotid and toe photoplethysmograms

ORCID Icon, , &
Pages 567-589 | Received 07 Oct 2021, Accepted 10 May 2022, Published online: 08 Jul 2022
 

Abstract

Blood pressure (BP) is a vital health parameter that varies throughout the day. As a single reading of high BP may not indicate hypertension, continuous monitoring of BP is usually recommended by medical doctors to confirm the diagnosis of hypertension. In the last few decades, researchers have investigated cuff-less and continuous BP measurements based on pulse transit time (PTT). The main purpose of this research is to develop an autoregressive (ARX) system identification (SI)-based PTT calculation model using two PPG signals acquired from carotid and toe. The signals were recorded from 65 subjects with an age range between 20 and 60 years. The results of the study have been validated in two stages. The first validation comprised the estimated BP from PTT using SI compared to the measured BP using the cuff-based method for all subjects. The results of the estimated BP using the proposed method compared to the measured BP obtained using the standard BP cuff measurement method are highly correlated to both systolic blood pressure (R2 = 0.8132) and diastolic blood pressure (R2 = 0.8357). The second validation consisted of comparing PTT values using system identification to the results of the PTT derived from the ECG–PPG method. The results showed that both methods are highly correlated (R2 = 0.7808), and there is no significant difference between them (p < 0.05) with a slightly better PTT estimation related to DBP in the proposed method. Our results have proven that the PTT obtained from the carotid PPG and toe PPG using the system identification approach yielded SBP and DBP estimations that are consistent with the values of the conventional BP cuff method. The newly proposed method has the advantage of being cuff-less and able to provide continuous BP measurements.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Additional information

Funding

The authors would like to acknowledge the partial financial support received from the Ministry of Higher Education Malaysia [TRGS/1/2019/UKM/01/4/3].

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.