Publication Cover
Journal of Environmental Science and Health, Part B
Pesticides, Food Contaminants, and Agricultural Wastes
Volume 53, 2018 - Issue 7
329
Views
6
CrossRef citations to date
0
Altmetric
Articles

Development and validation of HPLC methods for analysis of chlorantraniliprole insecticide in technical and commercial formulations

Pages 411-422 | Received 16 Aug 2017, Accepted 10 Jan 2018, Published online: 06 Mar 2018
 

ABSTRACT

Effective, selective, precise and accurate liquid chromatographic analytical methods for the analysis of a novel chlorantraniliprole insecticide in technical and formulation (coragen, 20% SC) have been optimized and validated. Eight methods were designed based on different mobile phases, temperature and two HPLC columns. The mobile phase consists of two mixtures (acetonitrile:water, 70:30 and methanol:water, 70:30) with 25 or 40ºC. HPLC analysis of chlorantraniliprole was carried out at a wavelength of 260 nm, with a flow rate of 0.8 mL/min. The calibration curves showed a good linear relationship (R2 ˃ 0.99) in the injected quantities ranged from 0.0125 to 1.00 μg. Limit of detection (LOD) was found to be 3.94 to 14.56 ng and from 5.95 to 12.93 ng using the analytical methods I to IV by MicroPack CN-10 and V-VIII by ZORBAX Eclips Plus C18 columns, respectively, based on SDslope values. ZORBAX Eclips Plus C18 column with method VI was the best one (R2 = 1.00 and RSD = 0.30), short retention time (4.936 min), high theoretical plates per column (65457.15) compared to others and LOD = 6.49 ng. The accuracy of the best method was demonstrated by recovery rates of 83.04% to 98.50% for grape samples supplemented with 5, 10 and 50 mg chlorantraniliprole/kg.

Conflict of interest

The authors declare that there is no conflict of interests regarding the publication of this paper.

Acknowledgments

The authors would like to extend their sincere appreciation to the Misr El Kheir Foundation: Science, Technology and Innovation (STI) Program to support this work under the project code LGA05130114.

Additional information

Funding

Misr El Kheir Foundation: Science, Technology and Innovation (STI) (LGA05130114).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.