Publication Cover
Hemoglobin
international journal for hemoglobin research
Volume 30, 2006 - Issue 4
149
Views
8
CrossRef citations to date
0
Altmetric
Original Article

Accurate Measurements of Fetal Hemoglobin for Neonates with Different Gestational Ages

&
Pages 419-435 | Received 20 Jan 2006, Accepted 12 Apr 2006, Published online: 07 Jul 2009
 

Abstract

The purposes of this study were to examine the accuracy of fetal hemoglobin (Hb F, α2γ2) as quickly measured by a hemoximeter but verified by high performance liquid chromatography [HPLC, including Hb F total (Hb Ft), acetylated Hb F (Hb F1), and non acetylated Hb F ( Hb F*)], and to predict the Hb F levels for different gestational weeks of neonates. Thirty-nine neonates of predominantly Hispanic and African American ethnicity, with gestational ages ranging from 25 to 38 weeks, were investigated. Analyses were performed on 163 blood samples that were pure neonates’ blood before the transfusion of any adult blood. Two neonates had increased Hb C [β6(A3)Glu→Lys, GAC→AAG] levels (1.67–2.79%) and one neonate whose mother drank alcohol during pregnancy, had elevated Hb A2 levels (0.12–0.14%). After excluding these data points, the mean Hb F were overestimated by hemoximeter, 118.4 ± 8.77% vs. 92.6 ± 2.77% by HPLC (mean difference: 25.8 ± 7.71%, p = <0.001). Mean Hb F1 was 10.5 ± 2.28%. Hb F levels decreased as gestational age increased (p <0.001 for Hb Ft and Hb F*; p = <0.05 for Hb F1). A multivariate regression model for Hb F prediction was established with the best R2. The gestational age and post birth hours in the prediction of Hb Ft was included when Hb F could be determined at the clinical settings. Future studies may be needed to account for Hb F1 when measuring Hb F levels to assess oxygenation status in (pre term) neonates.

Notes

HPLC = high-performance liquid chromatograph, HbF = fetal hemoglobin, HbFt = total Hbf, HbF* = non-acetylated Hbf, HbF1 = acetylated HbF, HbA = adult hemoglobin.

15. Krzeminski A. How is fetal hemoglobin determined and corrected for in the OSM3, the ABL510, and the ABL 520. Radiometer Copenhagen; May 1992. Info, No:1992-4,1-4.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.