ABSTRACT
The common point-to-point methods based on impedance measurements are quite laborious, though reliable, if the Q is to be determined over a wide range of frequencies to which the cavity is tunable. Therefore, the sweep frequency method of measurement of Q of a single ended cavity resonator (type X-13 reflex klystron) was studied using a hybrid circuit, i.e. magic tee.