Abstract
An active RC realization scheme of an SL impedance with a differential input paraphase amplifier is described. In effect the network is a capacitance loaded lossy gyrator and simulates a lossy inductor. Its flexibility of operation in practice is also discussed and appropriate sensitivity functions are evaluated.