Accommodative response to ocular surface pain

ORCID Icon &
Pages 624-630 | Received 11 Aug 2020, Accepted 07 Apr 2021, Published online: 28 Jul 2021
 

ABSTRACT

Clinical relevance

The discovery of an accommodative response to ocular surface stimulation could inform clinicians and patients that optical effects may occur due to ocular discomfort and perhaps an assessment of the accommodative system after carrying out interventions impacting the ocular surface, may be warranted.

Background

There have been no previous reports evaluating the effect of noxious stimulation on accommodation. Here, the accommodative response of healthy participants after the application of noxious corneal stimulation is characterised.

Methods

A computerised Belmonte pneumatic esthesiometer was used to determine detection thresholds (using ascending method of limits), and to randomly deliver mechanical and chemical stimuli from levels of detection threshold to twice the threshold in 50% steps, to the central cornea of 15 healthy subjects. For each suprathreshold stimulus, accommodative and pupil responses were measured with a validated eccentric infrared photorefractor. Quantitative differences in accommodative/pupil response, stimulus modality/intensity and left/right eye were analysed using repeated measures ANOVA. Tukey HSD tests were used for all post hoc analyses.

Results

Accommodation increased from baseline as the corneal apical stimulus intensity increased. This happened regardless of whether mechanical or chemical stimulation occurred (ANOVA, p < 0.05). At 200% threshold, accommodative response was greater than all stimulus intensities (Tukey HSD, all p < 0.05). There was no difference in pupil response between the stimulation intensities (100%, 150% and 200% threshold). There was no difference in accommodative response between the left and right eye for mechanical (ANOVA, p > 0.05) and chemical stimulation (ANOVA, p > 0.05).

Conclusion

Noxious stimulation of the cornea seems to produce a dose-dependent increase in the accommodative response in the eyes but not a dose-dependent pupil response.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Additional information

Funding

This work was supported by the Natural Sciences and Engineering Research Council of Canada [Discovery Grant 101,PDF 53274]; Canadian Foundation for Innovation [Infrastructure Grant 51].

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.