Study on heat transfer characteristic parameters and cooling effect of cold wall cooling system in coal mines

, , , &
Pages 179-196 | Received 16 Apr 2018, Accepted 25 Jan 2019, Published online: 20 Feb 2019
 

ABSTRACT

The paper designed a new type of mine cooling method. A small-scale experimental device was used to study the heat transfer characteristic parameters of the water film board of the core component of the method. Combined with the heat transfer model and experimental data, the average thermal conductivity and heat-absorbing efficiency were calculated to 0.0085 W/m·K and 85%. By setting different heat flux values, the roadway temperature dropped by 5.6°C to 22.1°C at a water flow rate of 25 ml/s. The paper also calculated the temperature rise value of a 100-m-long actual roadway after installing the cooling system through numerical simulation.

Nomenclature

A=

area (m2)

cw=

specific heat capacity of water (J/kg∙°C)

g=

acceleration of gravity (m/s2)

Hd=

height of water film board (m)

h=

convection heat transfer coefficient (W/m2·K)

k=

thermal conductivity (W/m·K)

kair=

thermal conductivity of dry air(W/m·K)

L=

thickness (m)

n=

number

NuL=

average Nusselt number

Pr=

Prandtl number

q=

thermal power (W)

qs=

electric power (W)

Q=

total heat absorbed by water (W)

r=

radius (m)

RaL=

Rayleigh number

T=

absolute temperature (°C)

T=

air temperature (°C)

Ts=

surface temperature (°C)

Tf=

temperature of heating film (°C)

ΔT=

temperature difference (°C)

vw=

velocity of water (m/s)

Greek letters

α=

coefficient of thermal diffusion (m2/s)

β=

coefficient of thermal expansion (K−1)

ν=

kinematic viscosity (m2/s)

ξ=

thermoelectric conversion rate

ηs=

heat absorption efficiency of a single water film board

ηf=

heat absorption efficiency of the cold wall cooling system

ρ=

density of dry air (kg/m3)

ρw=

density of water (kg/m3)

Subscripts

1=

outside

2=

inside

a=

insulation layer

b=

reflective film

c=

roadway frame

d=

water film board

in=

inward

k=

the rest

out=

outward

x=

x axis

w=

water

Acknowledgments

The authors are grateful for the support from the Fundamental Research for the Central Universities (grant No. 2018CXNL08).

Correction Statement

This article has been republished with minor changes. These changes do not impact the academic content of the article.

Additional information

Funding

This work was supported by the Fundamental Research Funds for the Central Universities [grant No. 2018CXNL08].

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.