CT Analysis of a Potential Safe Zone for Placing External Fixator Pins in the Humerus: A Commentary

Application of external fixators for comminuted, open, or unstable elbow injuries is not infrequent, and carries the risk of iatrogenic injury to the radial nerve via pin placement [Citation1–4]. This cadaveric CT-based investigation reports on the placement location and angle of external fixator pins in an effort to minimize this injury risk [Citation5]. There have been other anatomic studies of the radial nerve, but these largely focus on the location of the nerve laterally, and not in a more three-dimensional manner [Citation6, Citation7]. This investigation found that the proximal anterolateral area and distal posterolateral areas of the humerus are the relatively safe quadrants for half-pin placement, and the authors recommend placement into these two areas to minimize risk to the radial nerve.

As the distal humerus is not a simple cylinder, half-pin placement can be more difficult if attempting to insert into the lateral crest. Therefore, the authors recommend placing distal pins approximately 50 mm from the center of rotation of the elbow with an insertion angle of 30–45 degrees aiming anterior to avoid the lateral crest and more anterior radial nerve. If the surgeon was to aim from anterior to posterior at 30 degrees, the nerve was found at a mean of 58.3 mm from the elbow, and the risk of injury from the drill sleeve or even pin would be very significant; the distance from nerve to elbow was nearly doubled with a posterior to anterior insertion angle. However, the triceps tendon and injury to this is critical to avoid in order to optimize elbow motion and decrease scarring of the triceps. This is why a straight posterior elbow fixation pin placement is not recommended, and this study validates pin placement away from the tendon in a safe manner.

Most of the other anatomical investigations about radial nerve locations in relation to humerus or elbow fixation constructs rely on palpable or other easy to identify structures, whereas this investigation used the wire placed for a hinged external fixator as the location from which to measure from. Clinically, this would be very helpful if placing a hinged external fixator, as this wire would be in place, but results from this study also can be extrapolated to intraoperative use by locating this wire position via C-arm and then measuring from this spot. Despite the well described location in this analysis, I would recommend avoidance of purely percutaneous insertion of the distal humeral half-pins, as anatomic locations of the radial nerve and other structures can be altered with bony and soft tissue injury, and avoidance of iatrogenic injury to the radial nerve is critical to obtain an optimal outcome.

DECLARATION OF INTEREST

The author has no relevant or other financial disclosures for this invited commentary.

References

  • Baumann G, Nagy L, Jost B. Radial nerve disruption following application of a hinged elbow external fixator: a report of three cases. J Bone Jt Surg. 2011;93(10):e51.
  • Caldwell JM, Kim HM, Levine WN. Radial nerve injuries associated with application of a hinged elbow external fixator: a report of 2 cases. J Shoulder Elbow Surg. 2013;22(3):e12–e16. doi:10.1016/j.jse.2012.11.012.
  • Poglia P, Wehrli L, Steinmetz S, et al. Radial nerve palsy after the use of an adjuvant hinged external fixator in a complex fracture-dislocation of the elbow: a case report and review of the literature. J Med Case Rep. 2016;10(1):121. doi:10.1186/s13256-016-0904-9.
  • Trigo L, Sarasquete J, Noguera L, et al. radial nerve injuries following elbow external fixator: report of three cases and literature review. Arch Orthop Trauma Surg. 2017;137(7):953–957. doi:10.1007/s00402-017-2711-1.
  • Ye J, Li Q, Chen Z, et al. CT analysis of a potential safe zone for placing external fixator pins in the humerus. J Invest Surg. 2021;34(4):419–425. doi:10.1080/08941939.2019.1638471.
  • Gausepohl T, Koebke J, Pennig D, et al. The anatomical base of unilateral external fixation in the upper limb. Injury. 2000;31:11–20. (1) doi:10.1016/S0020-1383(99)00258-2.
  • Bono CM, Grossman MG, Hochwald N. Radial and axillary nerves. Anatomic considerations for humeral fixation. Clin Orthop Relat Res. 2000;373:259.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.