The Spiral of Tillaux: dead on accurate; a cadaveric study

, BA, , DO, , BA, , BAORCID Icon, , BA & , MD
 

ABSTRACT

Introduction

The Spiral of Tillaux describes the historically accepted insertion distances of the medial rectus, inferior rectus, lateral rectus, and superior rectus from the limbus: 5.5 mm, 6.5 mm, 6.9 mm, and 7.7 mm, respectively. The corneal diameters are historically accepted to be 11.7 mm horizontally and 10.6 mm vertically in adults. We investigated the variability of the insertion distances of the extraocular rectus muscles from the limbus as well as the corneal diameters using eyes from human cadavers and compared our measurements to these historically accepted measurements.

Methods

A sample of 60 eyes were included. For each eye, a 360 peritomy was conducted and the conjunctiva bluntly dissected to view the sclera. Muscle hooks were utilized to isolate the extraocular rectus muscles. Calipers were used to measure the insertion distances of the rectus muscles as well as the corneal diameters.

Results

The mean rectus muscle insertions distances from the limbus were medial 5.28 mm, inferior 5.72 mm, lateral 6.40 mm, and superior 6.78 mm. These insertion distances were shorter than the historical benchmarks (p < .01). However, observed maximum distances of the rectus muscles were all greater than the historically accepted benchmarks, with the medial, inferior, lateral, and superior rectus muscles being 6.4 mm, 7.3 mm, 7.4 mm, and 7.8 m from the limbus, respectively. The mean width and height of the cornea were 11.7 mm and 10.7 mm, respectively, and similar to the expected ranges.

Conclusion

This study concludes that variability does exist from the historically accepted Spiral of Tillaux measurements. In addition, significant variation exists between male and female rectus muscle insertions. However, we did confirm that the rectus muscles followed the same spiral pattern described by the Spiral of Tillaux and concluded that the corneal diameters are consistent with previously accepted values.

Acknowledgements

We thank Dr. Beth Brainerd, PhD, Department of Anatomy, the Warren Alpert Medical School, for access to the anatomy laboratory and assistance in collecting demographic data.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Additional information

Funding

The author(s) reported there is no funding associated with the work featured in this article.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.