350
Views
1
CrossRef citations to date
0
Altmetric
Article

Quantification of platelet function - a comparative study of venous and arterial blood using a novel flow cytometry protocol

, , , , ORCID Icon, , & show all
Pages 926-934 | Received 24 Jun 2021, Accepted 02 Dec 2021, Published online: 24 Jan 2022
 

Abstract

Studies of platelet function in surgical patients often involve both arterial and venous sampling. Possible effects of different sampling sites could be important, but have not been thoroughly investigated. We aimed to compare platelet function in arterial and venous blood samples using a novel flow cytometry protocol and impedance aggregometry. Arterial and venous blood was collected before anesthesia in 10 patients undergoing cardiac surgery of which nine was treated with acetylsalicylic acid until the day before surgery. Flow cytometry included simultaneous analysis of phosphatidylserine exposure, active conformation of the fibrinogen receptor (PAC-1 binding), α-granule and lysosomal release (P-selectin and LAMP-1 exposure) and mitochondrial membrane integrity. Platelets were activated with ADP or peptides activating thrombin receptors (PAR1-AP/PAR4-AP) or collagen receptor GPVI (CRP-XL). Leukocyte-platelet conjugates and P-selectin exposure were evaluated immediately in fixated samples. For impedance aggregometry (Multiplate®), ADP, arachidonic acid, collagen and PAR1-AP (TRAP) were used as activators. Using impedance aggregometry and in 27 out of 37 parameters studied with flow cytometry there was no significant difference between venous and arterial blood sampling. Arterial blood showed more PAC-1 positive platelets when activated with PAR1-AP or PAR4-AP and venous blood showed more monocyte-platelet and neutrophil-platelet conjugates and higher phosphatidylserine exposure with CRP-XL alone and combined with PAR1-AP or PAR4-AP. We found no differences using impedance aggregometry. In conclusion, testing of platelet function by flow cytometry and impedance aggregometry gave comparable results for most of the studied parameters in venous and arterial samples. Flow cytometry identified differences in PAC-1 binding when activated with PAR1-AP, exposure of phosphatidyl serine and monocyte/neutrophil-platelet conjugates, which might reflect differences in blood sampling technique or in flow conditions in this patient cohort with coronary artery disease. These differences might be considered when comparing data from different sample sites, but caution should be exercised if a different protocol is used or another patient group is studied.

Disclosure statement

No potential conflict of interest was reported by the author(s).

Authors contributions

Mattias Törnudd, designed the study, performed experiments, interpreted the data, and wrote the manuscript; Mohamad Rodwan Al Ghraoui, Sofia Wahlgren and Erik Björkman performed experiments; John-Peder Escobar Kvitting and Joakim Alfredsson interpreted the data, and wrote the manuscript; Sofia Ramström and Sören Berg designed the study, interpreted the data and wrote the manuscript.

Supplementary material

Supplemental data for this article can be accessed on the publisher’s website.

Additional information

Funding

This work was supported by County Council of Östergötland (LIO-661221; LIO-603321) and departmental sources.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.