Abstract
In this study, a conjugate gradient method based inverse algorithm is applied to estimate the unknown three-dimensional fouling-layer profiles on the inner wall of a piping system using simulated temperature measurements taken on the pipe wall. The temperature data obtained from the direct problem are used to simulate the exact temperature measurements. Results show that an excellent estimation on the fouling-layer profiles can be obtained for the two cases investigated in this study. The technique presented here can be used as an alternative to ultrasonic waves fouling detection techniques to provide crucial information for the optimization of cleaning schedule for piping systems.
This work was supported by the National Science Council, Taiwan, Republic of China, under the grant numbers NSC 97-2221-E-168-041 and NSC 97-2221-E-168-039.