121
Views
2
CrossRef citations to date
0
Altmetric
Research Articles

Aquatic, deep water peak VO2 testing for individuals with spinal cord injury

ORCID Icon, , , &
 

Abstract

Objective: To determine the reliability of peak VO2 testing for individuals with spinal cord injury (SCI) in deep water and on land; and to examine the relationship between these two testing conditions.

Design: Reliability study.

Setting: Comprehensive rehabilitation center in Baltimore, MD, USA.

Participants: 17 participants (13 men, 4 women) with motor complete and incomplete SCI. Participants were randomized into either aquatic or arm cycle ergometer first measurements.

Intervention: Pilot study to assess peak VO2.

Outcome measures: Peak VO2 measured with metabolic cart in supported deep water with the addition of Aquatrainer® connection, and on land with arm cycle ergometer. Two trials were conducted for each condition with 48 h separating each test.

Results: Peak oxygen consumption reliability was statistically significant for both conditions, aquatic (r = 0.93, P < 0.001) and arm cycle ergometry (r = 0.96, P < 0.001). Additionally, aquatic and arm cycle peak VO2 correlation existed (r = 0.72, P < 0.001). For these 17 participants, lower extremity motor score influenced supported, deep water peak VO2, B = 0.57, P < 0.02, whereas age, sex, and weight did not impact deep water or ergometer values.

Conclusion: Determining peak VO2 for individuals with SCI is highly reproducible for arm cycle ergometry and in deep water assessment. Additionally, aquatic, deep water peak VO2 testing is valid when compared to arm cycle ergometry. Although the peak VO2 relationship between deep water and arm cycle ergometry is high, variance in the two conditions does exist. Therefore, it is important to assess peak VO2 via the same exercise modality utilized in the treatment intervention.

Acknowledgements

We appreciate the time and effort of all patients who eagerly participated in this study. We thank the facilities engineer who constructed our modified Aquatrainer testing system.

Disclaimer statements

Contributors None.

Funding The Kernan Endowment Fund purchased the Aquatrainer and covered testing structural modification cost. Kosciuszko Foundation funded the scholarship for one of the researchers.

Conflicts of interest Authors have no conflicts of interest to declare.

ORCID

Anna Ogonowska-Slodownik http://orcid.org/0000-0002-3318-6513

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.