Permeability of Medical Gloves to Mono- and Dimethacrylate Monomers in Dental Restorative Materials

&
Pages 497-509 | Published online: 08 Jan 2015
 

Abstract

Dental personnel manually handle methacrylate-based restorative materials, which can cause skin irritation and allergies. The protection given by different types of medical gloves is not well known. Breakthrough time (BTT, min) was used as a measure of protection according to a European standard, using 2 test mixtures consisting of respectively 3 and 5 monomers. Fourteen gloves representing natural rubber latex, synthetic rubber, and synthetic polymeric material were tested. The BTT ranged from some minutes to more than 2 hrs for the 4 monomers with a molecular mass less than 300. The longest protection was recorded for Nitra Touch (nitrile rubber), Tactylon (synthetic rubber), and Metin (PVC).