ABSTRACT
To fill space of the code existing in the field of the confined masonry as in level French as European, the CSTB leads a search program of walls built in full scale. In this article, are presented the results of these various types of clay masonry pieces, these pieces taken up according to various modes of arrangement of vertical joints (empty, full, intermediate situation). Walls are subjected to the action of an alternated cyclic horizontal load, applied in the plan of the wall. The failure mechanisms of these walls show the influence of the aspect ratio and the mechanical characteristics of bricks. A model simplified of compression diagonal failure of the wall is besides proposed. This model integrates the mechanical characteristics of the used elements, as well as the geometrical characteristics of the wall.
RÉSUMÉ
Afin de réunir les éléments de connaissance utiles dans le domaine des maçonneries de contreventement tant au niveau français qu'européen, le CSTB mène un programme expérimental de recherche. Dans cet article sont présentés les résultats de différents essais sur des murs de maçonneries en éléments de terre cuite, montés selon différents modes de jointoiements verticaux. Les murs sont soumis à l'action d'une charge horizontale cyclique alternée, appliquée dans le plan du mur. L'analyse des modes de rupture de ces murs, menée en collaboration avec l'université de Mame-la-Vallée, montre l'influence de 1'élancement et du caractère orthotrope des briques. Un modèle simplifié de charge de rupture du mur par bielle de compression est également proposé. Ce modèle intègre les caractéristiques mécaniques des éléments utilisés, ainsi que les caractéristiques géométriques du mur.