ABSTRACT
This paper presents a statistical study on fundamental frequency of vibration of a set of buildings situated in urban area of Grenoble (France). Correlations are established between the frequency and some building parameters (height, width, materials, type of structure). The formulas given by these correlations are compared with the ones of French Seismic Code PS92, Algerian Seismic Code RPA88 and American Seismic Code UBC88. A new formula for fundamental period for RC concrete shear walls buildings is proposed. This study has shown that fundamental frequencies of many buildings are situated in the amplification frequency range of the Grenoble site. Following this last result, a preliminary vulnerability study is started in order to estimate the seismic risk incurred by existing constructions.
RÉSUMÉ
La présente étude traite de l'estimation de la fréquence fondamentale de vibration d'un certain nombre de bâtiments situés dans l'agglomération de Grenoble (France). Des corrélations sont établies entre cette fréquence et certains paramètres (hauteur, largeur, matériau, type de structure) de l'édifice. Les formules résultantes de ces corrélations sont comparées aux formules des règles parasismiques françaises PS92, algériennes RPA88 et américaines UBC88. Une nouvelle formule de la période fondamentale de bâtiments à murs porteurs en béton armé est proposée. Cette étude a montré que les fréquences fondamentales de beaucoup de ces bâtiments se situent dans la plage de fréquences d'amplification du site particulier de Grenoble. Suite à ceci une amorce d'étude de vulnérabilité au séisme a été entamée pour estimer le risque encouru par le bâti existant.