435
Views
8
CrossRef citations to date
0
Altmetric
Original Articles

The need for a revised version of the Benton judgment of line orientation test

&
Pages 249-256 | Received 17 Nov 2009, Accepted 12 Jun 2010, Published online: 30 Sep 2010
 

Abstract

The Judgment of Line Orientation Test (JLOT) is considered a valid task for the assessment of visuospatial perception, and, for this reason, it is also considered to be a sensitive tool able to discriminate between right-hemisphere-damaged (RHD) patients and left-hemisphere-damaged (LHD) patients. In contrast with this view, we report evidence that the greater impairment in JLOT usually shown by RHD patients is unrelated to the supposed JLOT effectiveness in measuring visuospatial judgment ability and to the putative dominant role of the right hemisphere in visuospatial processing. JLOT is characterized by a left–right structural asymmetry (i.e., left-side lines are easier to judge) that seriously undermines the test validity: This asymmetry interacts with ipsilesional attentional biases of brain-damaged patients and affects their performance. Results obtained with a JLOT version composed of both the original items and their mirror-reversed versions clearly indicate that the cognitive functions tested by the JLOT are distributed across the two hemispheres: LHD and RHD patients did not differ from each other or from their matched controls when their performances were compared on this balanced JLOT version. Impaired performances of either RHD or LHD patients were found only when performances in original and mirror-reversed items were considered separately. This suggests that the original JLOT cannot assess visuospatial perception independently from attentional biases. The test can be a powerful clinical tool, as long as both original and mirror-reversed items are used, and the standard scoring method is replaced by the evaluation of the individual lines of stimulus pairs.

This study was supported by a grant from Fondazione San Paolo, Neuroscience Programme.

Notes

1In the standard JLOT there are seven line segments corresponding to Line 1 and seven segments corresponding to Line 5, as opposed to six segments corresponding to Line 11 and six segments corresponding to Line 7 (see CitationTreccani et al., 2005, for a detailed analysis of the influence of the line slope on JLOT performance).

2The Leven test for homogeneity of variance was performed on the score variances of the four groups of patients (i.e., the two groups of patients and the two control groups). This analysis indicated that the variances were homogeneous in both item versions and spatial sides (all Fs ≤ 1.57, all ps ≥ .2).

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.