948
Views
1
CrossRef citations to date
0
Altmetric
Jumping

The effects of limb dominance and a short term, high intensity exercise protocol on both landings of the vertical drop jump: implications for the vertical drop jump as a screening tool

, , , , &
Pages 541-553 | Received 07 Oct 2016, Accepted 18 Aug 2017, Published online: 18 Sep 2017
 

Abstract

The effectiveness of vertical drop jumps (VDJs) to screen for non-contact ACL injuries is unclear. This may be contributed to by discrete point analysis, which does not evaluate patterns of movement. Also, limited research exists on the second landing of VDJs, potential lower limb performance asymmetries and the effect of fatigue. Statistical parametric mapping investigated the main effects of landing, limb dominance and a high intensity, intermittent exercise protocol (HIIP) on VDJ biomechanics. Twenty-two male athletes (21.9 ± 1.1 years, 180.5 ± 5.5 cm, 79.4 ± 7.8 kg) performed VDJs pre- and post-HIIP. Repeated measures ANOVA identified pattern differences during the eccentric phases of the first and second landings bilaterally. The first landing displayed greater (internal) knee flexor (η2 = 0.165), external rotator (η2 = 0.113) and valgus (η2 = 0.126) moments and greater hip (η2 = 0.062) and knee (η2 = 0.080) flexion. The dominant limb generated greater knee flexor (η2 = 0.062), external rotator (η2 = 0.110) and valgus (η2 = 0.065) moments. The HIIP only had one effect, increased thoracic flexion relative to the pelvis (η2 = 0.088). Finally, the dominant limb demonstrated greater knee extensor moments during the second landing (η2 = 0.100). ACL injury risk factors were present in both landings of VDJs with the dominant limb at potentially greater injury risk. Therefore, VDJ screenings should analyse both landings bilaterally.

Acknowledgements

The authors express their gratitude to the athletes who volunteered to participate in this study. The authors have no conflicts of interest or external funding sources to disclose. We would like to acknowledge the contributions of John Whyte and Tom O’Malley (JTEC Ltd, Dundalk, Ireland) in the design and manufacture of the custom made circuit used to integrate the motion analysis and light gate systems.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.