152
Views
3
CrossRef citations to date
0
Altmetric
Original Article

Prelabour myocardial deformation and cardiac output in fetuses that develop intrapartum compromise at term: a prospective observational study

ORCID Icon, , , & ORCID Icon
Pages 3618-3626 | Received 22 Dec 2017, Accepted 22 Apr 2018, Published online: 09 May 2018
 

Abstract

Objective: Redistribution of cardiac output is responsible for the “brain sparing” effect seen during periods of acute or chronic fetal stress. We investigated the relationship between prelabour cardiac function in fetuses that subsequently developed intrapartum fetal compromise (IFC).

Methods: A blinded, prospective, observational, cohort study, at Mater Mother’s Hospital, Brisbane, Australia. A cohort of 284 women with uncomplicated singleton pregnancies underwent ultrasound every 2 weeks from 36 weeks until delivery. Fetal cardiac output was assessed by conventional Doppler ultrasound and myocardial deformation was measured using velocity vector imaging.

Results: Two hundred and seventy three women were included in the final analysis, of which 19% had an emergency operative delivery for intrapartum fetal compromise (IFC). Global left ventricular strain (−12.1%, interquartile ranges (IQR) − 10.3 to −14% versus 13%, IQR −11.3 to −14.2%, p = .01) and strain rate (−1.00, IQR 0.85–1.16 s−1 versus −1.11, IQR −1.00 to −1.21 s−1, p < .001) were lower in fetuses that required any emergency operative delivery for IFC compared to those that did not. Global longitudinal right ventricular strain rate was lower in fetuses that developed IFC (−1.04 ± 0.22 s−1 versus 1.13 ± 0.22 s−1, p < .001), whereas global right ventricular strain did not show any significance differences between the two groups. Additionally, left ventricular cardiac output was lower in fetuses that developed IFC or had a composite neonatal morbidity (560 ± 44 mL/min versus 617 ± 72 mL/min, p < .001) or (581 ± 44 mL/min versus 612 ± 72 mL/min, p < .01), respectively.

Conclusion: Lower global left ventricular strain and strain rate and cardiac output are associated with IFC and poorer condition of the newborn. Assessment of fetal cardiac function may be useful for risk stratification for intrapartum fetal compromise in apparently “low risk” term pregnancies.

Acknowledgements

The authors acknowledge the research support by the Mater Foundation.

Disclosure statement

No potential conflict of interest was reported by the authors.

Reprints and Corporate Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

To request a reprint or corporate permissions for this article, please click on the relevant link below:

Academic Permissions

Please note: Selecting permissions does not provide access to the full text of the article, please see our help page How do I view content?

Obtain permissions instantly via Rightslink by clicking on the button below:

If you are unable to obtain permissions via Rightslink, please complete and submit this Permissions form. For more information, please visit our Permissions help page.